货号 | 383223 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
简介 | For multiplex amplification of 12 X-chromosomal STRs, D21S11 and Amelogenin, with an innovative Quality Sensor | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
描述 | Performance The Investigator Argus X-12 QS Kit utilizes fast-cycling technology to provide reliable results in approximately 80 minutes.The novel Fast Reaction Mix 2.0 is based on proven QIAGEN Multiplex PCR technology that has been further optimized for direct amplification. Assay performance tests in the presence of increasing concentrations of inhibitors showed superior inhibitor resistance. This means reliable, high-quality results. The Investigator Argus X-12 QS Kit was validated and evaluated using the GeneAmp 9700 thermal cycler (in standard mode) and the Applied Biosystems 3500 Genetic Analyzer. Principle The Investigator Argus X-12 QS Kit uses QIAGENs fast-cycling PCR technology for the direct, simultaneous amplification of 12 X-chromosomal markers, D21S11 and Amelogenin. The amplification of the 12 X-chromosomal markers (see Table 1 and 2), with heightened discrimination power, meets the needs for complex kinship and paternity testing and helps fulfill the demands of complicated deficiency cases involving at least one female. The 12 X-chromosomal markers are clustered into four linkage groups (three markers per group; Table 1), and thus each set of three markers is handled as a haplotype for genotyping.
The innovative Quality Sensors provides additional information on the sample quality and PCR success beyond the profile of your sample. With the Quality Sensor (QS) being amplified as an amplification control, it is possible to determine:
This additional information will help you analyze your data, and guides you with respect to further sample processing. It will also help you reduce unnecessary PCR re-runs, saving you time and money. The additional autosomal marker D12S11 acts as alignment marker. Now, you have the possibility to align your X-chromosomal profile from the Investigator Argus X-12 QS Kit with a profile of any other autosomal STR kit from the expanded CODIS or ESS market, to minimize the risk of sample mix-ups. Procedure The 12 X-chromosomal markers, D21S11 and the gender-specific Amelogenin, are amplified simultaneously in a single PCR run and labeled with one of the dyes listed in the Table 2: "Investigator Argus X-12 QS Kit dyes and corresponding markers".The amplified loci then undergo capillary electrophoresis. The results can be analyzed using dedicated software, such as Applied Biosystems GeneMapper ID-X. See the table "Technical specifications" for more information.
Applications The Investigator Argus X-12 QS Kit enables simultaneous amplification of 12 X-chromosomal markers, and is highly suitable for:
|
说明书 | ||
供应商 | Qiagen |